Creating a RAID 53 virtual disk array
The following procedure creates a RAID 53 (striped array of
arrays) virtual disk configuration
using previously configured RAID 5 virtual disk arrays
for its pieces.
See
``Striped array of arrays (RAID 53)''
for more information about this type of array.
-
Configure two or more RAID 5 virtual disk arrays using the
Virtual Disk Manager.
-
Restore parity on each RAID 5 array.
WARNING:
Do not create any filesystems at this stage.
-
Select New from the Disk menu, and choose
to add a RAID 53 array.
-
Select the RAID 5 arrays that you created in step 1 for
the pieces of the RAID 53 array.
-
The Virtual Disk Manager prompts you to create
a filesystem on the new array.
-
Exit from the Virtual Disk Manager.
-
Use the
Filesystem Manager to configure the filesystem's
mount point and mount options.
Your RAID 53 array is now online and ready for use.
Next topic:
Modifying virtual disks
Previous topic:
Creating a RAID 10 virtual disk array
© 2003 Caldera International, Inc. All rights reserved.
SCO OpenServer Release 5.0.7 -- 11 February 2003