If your system contains more than one type of host adapter, SCO OpenServer might find the secondary adapter first and assume it is the controller for the root disk. In this case, Upgrade might not be offered as an option for Installation type. If this happens, restart the installation and specify the location of your root hard disk at the boot prompt.
For example, if the root disk is at
ID 0 on the first bus of an Adaptec 294x host adapter,
enter the following at the boot prompt:
defbootstr Sdsk=alad(0,0,0,0)
If the root disk is on a second adapter of the same type, enter the
following:
defbootstr Sdsk=alad(1,0,0,0)
If you have a different SCSI host adapter, use the appropriate driver name instead of alad. The following table lists the supported SCSI host adapters and the corresponding driver names.
Host adapter | Driver name |
---|---|
Adaptec 151x, 152x (6260, 6360 Chips) &
SlimSCSI 1460 Adapters | smad |
Adaptec 154x, 164x, 174x (Standard mode) | ad |
Adaptec 174x (Enhanced mode) | eiad |
Adaptec 274x, 284x (7770 Chip) | arad |
Adaptec 2916x, 3916x (7892, 7899 Chips) | ad160 |
Adaptec 292x, Future Domain 16x0, 600, 700 (18x0 Chip) | fdhb |
Adaptec 294x, 394x, 494x (785X, 7860, 7870, 7880,
7895 Chips) & SlimSCSI 1480A/B Adapters | alad |
Adaptec 2940U2W, 2950U2B, 3950U2 (7890, 7891,
7897 Ultra2 Chips) | blad |
Advanced Micro Devices PCscsi | ams |
BusLogic MultiMaster Adapters | blc |
BusLogic FlashPoint Adapters | flashpt |
Compaq Array Controller | clad |
Compaq Fast-SCSI-2 Adapter | cha |
Compaq RAID 234234 Adapter | ida |
Compaq Intelligent Storage Subsystem | ciss |
Corollary 386/486 CBUS SCSI-CPU | ciha (*) |
DPT SCSI & RAID Adapters | dptr |
Enhanced IDE, ATAPI Interface | wd |
Future Domain (formerly Western Digital) 7000 | wdha (*) |
Future Domain (formerly Western Digital) 7000EX | wdex (*) |
Future Domain 845, 850, 860, 885 (950 Chip) | tmcha (*) |
IBM HardFile Adapters | hf |
Intel SRCMR, SRCU-31, SRCU-31L,
SRCU-32 Server
RAID Adapters | iir |
LSI Logic/Symbios Logic/NCR MPD 53c8xx Adapters | slha |
Mylex Disk Array Controller | mdac |
NCR Microchannel Systems Adapters | ncr (*) |
Olivetti ESC-1, ESC-2, and EFP Adapters | efp (*) |
Storage Plus SCSI-AT (SUMO) | sumo |
Tricord Intelligent I/O Processor | iiop/piiop (*) |
* | |
---|---|
These drivers are no longer supported by SCO, however they are still provided with SCO OpenServer for your convenience. Contact your hardware vendor for support. |
See the boot(HW) and bootstring(HW) manual pages and ``Using bootstrings'' for more information.